Q: What can I check if the water pump does not work?
A: If the pump switch light is not on, check the water pump fuse or circuit breaker. If the switch light is on, check the connections directly at the water pump for 12vdc (+) and (-). If both (+) and (-) are present at the pump connections, have the water pump replaced by qualified personnel. If you do not have both (+) and (-) at the water pump, locate the controller (latching relay), check for 12vdc (+) output to pump. If the controller does not have 12vdc (+) output to pump have the controller replaced by qualified personnel.